System Assessments

Analysis of the pressure data logging showed that, while the variable speed drive compressor maintained a constant discharge pressure near 120 psi, the pressure at various critical points fell to as low as 85 psi during peak production operations. General pressure in the plants, especially Plant 2, fluctuated between 102 and 112 psi, showing that the pressure/flow control valve was not regulating properly, and that Plant 2 lacked enough general storage volume to support transient flows.