A Compressed Air Piping System Assessment

During an Energy Review at a relatively new health care garment factory, in the Southwest, we found all three of the 100 psig nominally rated rotary screw air compressors were operating at 115-120 psig continuously. We asked the Production Superintendent if this was normal or if something had recently changed. He explained that initially they operated two air compressors but had to begin running the 3rd unit in ‘trim’ mode after some converting machines were up-graded. Then, a new larger converting machine was recently installed and air pressure quickly became a production issue. Since capital funds were tight, the project engineering team determined the third air compressor had sufficient capacity.

An Aging Plant Air System gets a Face-Lift

The Technical Director of a large facility in the Mid-West (producing valves and meters) hired us to assist with a Site Energy & Utility Systems assessment. The compressed air system quickly became one of the main issues identified. The plant was built in the 1960’s and had expanded over the years. Recent reduction-in-force programs (to reduce costs) had impacted the maintenance department and the plant air system was high among the systems that were the most affected. Over the next several months, as management became attuned to all of the air system issues affecting utility costs and process quality concerns, resources were provided and significant improvements occurred.

Plastic Molder Reduces $3.2 Million Energy Spend with Pneumatic Cylinder Retrofits

A plastics molding plant had engaged us to conduct an ‘on-site’ Energy Assessment of their facility. The annual ‘spend’ for electricity, natural gas, and water was about $3.2 million for this modern 275,000 square foot, fully air-conditioned facility. During the Review, several opportunities were identified and delineated in lighting, HVAC, process ventilation, the water systems and energy supply contracts. However, the most significant savings were in their compressed air system.

Sanity Check: Will the Standby Air Compressors Start-Up During Cold Weather?

Several days prior to our visit, during a cold winter evening, the lead air compressor in one mechanical room tripped off (apparently due to a fouled intake filter and low air flow through the machine). A crucial situation then developed: The "stand-by" unit did not start. Maintenance folks had to be called in to get a compressor running. That delay caused low plant air pressure, production curtailment and some defective product. They had yet to determine the conditions that caused the "no-start".

Compressed Air System Improvements

An industrial manufacturing plant (producing commercial water meters and valves) had engaged us to conduct an ‘on-site’ Energy & Utilities Assessment of their facility. The annual ‘spend’ for electricity, natural gas, fuels and water was about $ 2.0 million.

Compressed Air Piping Distribution Systems

Perhaps your facility recently had a compressed air system survey, conducted by an air systems services company, that resulted in a couple of major recommendations, such as: • Install a new smaller compressor and new control systems on all of the units • Repair the many air leaks (identified as 30% of your system capacity)